GroLine Combo Waterproof pH/EC/TDS/Temperature Tester
Couldn't load pickup availability
Product Details
Product Details
This is an updated version of the HI98129. The biggest difference between the existing HI98129 and the Groline HI98131 is that the Groline features the Quick Cal Mode, which allows you to calibrate the pH and EC/TDS with a single solution.
The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
The HI98131 GroLine tester features a large multi level LCD which displays both pH, EC or TDS and temperature readings simultaneously. The pH readings are displayed with a 0.01 resolution and with an accuracy of +/-0.05 pH, while the EC and TDS readings are displayed with a 0.01 mS/cm and 10 ppm (mg/L) resolution and 2% full scale accuracy. The EC range of the HI98131 is from 0.01 to 6.00 mS/cm and TDS is from 0 to 3000 ppm using a 0.5 conversion factor. The HI98131 also offers the option to use a 0.7 (700 ppm) EC to TDS conversion factor. An exposed temperature sensor allows for rapid temperature compensated measurements of EC and TDS. The LCD screen has indicators for calibration status and stability. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available. The HI98131 is a versatile pocket meter designed for hydroponics, greenhouse and agriculture applications.
Simplified one button calibration
One or two point pH calibration is automatic to a pre-programmed buffer set (4.01, 7.01 and 10.01) or single point pH and EC calibration with the Hanna Quick Cal calibration solution. To perform a quick cal calibration, simply press and hold the left power/mode button while in measurement mode for three seconds and let go to enter calibration mode. Once both pH and EC are calibrated "CAL OK" is displayed and the meter returns to measurement mode.
HI73127 Replaceable pH electrode
The HI99131 is supplied with the HI73127 replaceable pH electrode. This electrode features an extractable junction that can be pulled 1/8" out to clear any clogging that results in drifting and erratic readings.
Features at-a-glance
3 sensors in a single meter
- pH electrode with extractable junction
- Amperometric EC/TDS sensor
- Exposed temperature probe for faster EC/TDS readings
Waterproof
- Designed to withstand the humidity of a growing environment
- pH range is from 0.00 to 14.00 pH
Selectable EC to TDS conversion factor
- Choice of either a 0.5 or 0.7 conversion factor
- 0.5 (500 CF) conversion factor is for an EC reading of 1000 μS/cm = 500 ppm
- 0.7 (700 CF) conversion factor is for an EC reading of 1000 μS/cm = 700 ppm
Automatic Temperature Compensation
- All readings are compensated for variations in temperature
- Temperature displayed in oC or oF along with pH, EC or TDS reading
Stability indicator
- Meter displays a clock tag that will disappear when the reading has achieved stability
HOLD button
- Freezes reading on the display to allow recording of measurement
BEPS (Battery Error Prevention System
- Meter will automatically shut off if there is not enough power to get an accurate measurement
Battery % level at startup
Low Battery Indicator
- When the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.
Auto-off
- Selectable time before meter will automatically shuts off to conserve battery life. Options are after 8 minutes, 60 minutes , or disabled.
Specifications
| pH Range | 0.00 to 14.00 pH |
|---|---|
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.1 pH |
| pH Calibration | automatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution |
| Conductivity Range | 0.00 to 6.00 mS/cm |
| Conductivity Resolution | 0.01 mS/cm |
| Conductivity Accuracy | ±2% F.S. |
| TDS Range | 0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF) |
| TDS Resolution | 10 ppm (mg/L) |
| TDS Accuracy | ±2% F.S. |
| Temperature Range | 0.0 to 60.0°C / 32.0 to 140.0°F |
| Temperature Resolution | 0.1°C / 0.1°F |
| Temperature Accuracy | ±0.5°C /±1°F |
| Temperature Compensation | pH: automatic; EC/TDS: automatic with β set at 1.9%/°C |
| EC/TDS Calibration | automatic, one-point at 1.41 mS/cm or 5.00 mS/cm; one point calibration using quick calibration solution |
| TDS Conversion Factor | 0.5 (500 ppm) or 0.7 (700 ppm) |
| Battery Type/Life | 1.5V (4) / approx. 100 hours of continuous use, auto-off after 8 minutes of non-use |
| Auto-off | after 8 minutes, 60 minutes, disabled |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions | 163 x 40 x 26 mm (6.4 x 1.6 x 1.0’’) |
| Weight | 100 g (3.5 oz.) |
| Ordering Information | HI98131 is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries (4), instructions and quality certificate. |
Warranty Information: The fastest way to handle warranty issues is by contacting Hanna Instruments directly. If you prefer, you can always contact us directly and we will help facilitate the return. After purchasing your Hanna product, you may register for warranty on their website www.hannainst.com/hydroponics or retain your receipt as proof of purchase. Contact Hanna Tech Support with your valid proof of purchase at tech@hannainst.com or 800-426-6287 to be issued a Return Goods Authorization.
Specifications
Specifications
| Brand | Hanna |
|---|---|
| Part Number | HI98131 |
| Length | 7 in |
| Width | 2 in |
| Height | 1 in |
| Product Weight | 0.33 lb |
| Actual Product Weight | 0.33 lb |
| Warranty | Yes |