Our site just got a new paint job. There are still a few kinks to work out, please bear with us as we work through them. Thanks for your continued support!
FloraFlex 1/4 in Piercing Barbed Louver Insert (bag of 6)

FloraFlex 1/4 in Piercing Barbed Louver Insert (bag of 6)

Nanolux MaxPar CMH 315w Ceramic Metal Halide Lamp - 4K (4100K) Veg

Nanolux MaxPar CMH 315w Ceramic Metal Halide Lamp - 4K (4100K) Veg

GroLine Combo Waterproof pH/EC/TDS/Temperature Tester

was $259.95 Special Price $185.95
You save $74.00 (28.47%) off MSRP

This is an updated version of the HI98129. The biggest difference between the existing HI98129 and the Groline HI98131 is that the Groline features the Quick Cal Mode, which allows you to calibrate the pH and EC/TDS with a single solution. 

The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).

The HI98131 GroLine tester features a large multi level LCD which displays both pH, EC or TDS and temperature readings simultaneously. The pH readings are displayed with a 0.01 resolution and with an accuracy of +/-0.05 pH, while the EC and TDS readings are displayed with a 0.01 mS/cm and 10 ppm (mg/L) resolution and 2% full scale accuracy. The EC range of the HI98131 is from 0.01 to 6.00 mS/cm and TDS is from 0 to 3000 ppm using a 0.5 conversion factor. The HI98131 also offers the option to use a 0.7 (700 ppm) EC to TDS conversion factor. An exposed temperature sensor allows for rapid temperature compensated measurements of EC and TDS. The LCD screen has indicators for calibration status and stability. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.  The HI98131 is a versatile pocket meter designed for hydroponics, greenhouse and agriculture applications.

SKU
9448
Availability: In stock online - contact us for store pickup

This is an updated version of the HI98129. The biggest difference between the existing HI98129 and the Groline HI98131 is that the Groline features the Quick Cal Mode, which allows you to calibrate the pH and EC/TDS with a single solution. 

The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).

The HI98131 GroLine tester features a large multi level LCD which displays both pH, EC or TDS and temperature readings simultaneously. The pH readings are displayed with a 0.01 resolution and with an accuracy of +/-0.05 pH, while the EC and TDS readings are displayed with a 0.01 mS/cm and 10 ppm (mg/L) resolution and 2% full scale accuracy. The EC range of the HI98131 is from 0.01 to 6.00 mS/cm and TDS is from 0 to 3000 ppm using a 0.5 conversion factor. The HI98131 also offers the option to use a 0.7 (700 ppm) EC to TDS conversion factor. An exposed temperature sensor allows for rapid temperature compensated measurements of EC and TDS. The LCD screen has indicators for calibration status and stability. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.  The HI98131 is a versatile pocket meter designed for hydroponics, greenhouse and agriculture applications.

Simplified one button calibration

One or two point pH calibration is automatic to a pre-programmed buffer set (4.01, 7.01 and 10.01) or single point pH and EC calibration with the Hanna Quick Cal calibration solution. To perform a quick cal calibration, simply press and hold the left power/mode button while in measurement mode for three seconds and let go to enter calibration mode. Once both pH and EC are calibrated "CAL OK" is displayed and the meter returns to measurement mode.

HI73127 Replaceable pH electrode

The HI99131 is supplied with the HI73127 replaceable pH electrode. This electrode features an extractable junction that can be pulled 1/8" out to clear any clogging that results in drifting and erratic readings.

Features at-a-glance

 

3 sensors in a single meter

 

 

  • pH electrode with extractable junction
  • Amperometric EC/TDS sensor
  • Exposed temperature probe for faster EC/TDS readings

 

Waterproof

 

  • Designed to withstand the humidity of a growing environment
Wide pH Range
  • pH range is from 0.00 to 14.00 pH

Selectable EC to TDS conversion factor

  • Choice of either a 0.5 or 0.7 conversion factor
  • 0.5 (500 CF) conversion factor is for an EC reading of 1000 μS/cm = 500 ppm
  • 0.7 (700 CF) conversion factor is for an EC reading of 1000 μS/cm = 700 ppm

Automatic Temperature Compensation

  • All readings are compensated for variations in temperature
  • Temperature displayed in oC or oF along with pH, EC or TDS reading

Stability indicator

  • Meter displays a clock tag that will disappear when the reading has achieved stability

HOLD button

  • Freezes reading on the display to allow recording of measurement

BEPS (Battery Error Prevention System

  • Meter will automatically shut off if there is not enough power to get an accurate measurement

Battery % level at startup

Low Battery Indicator

  • When the level is below 5%, the  battery symbol on the LCD blinks to indicate a low battery condition.

Auto-off 

  • Selectable time before meter will automatically shuts off to conserve battery life. Options are after 8 minutes, 60 minutes , or disabled.
 

Specifications

pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.1 pH
pH Calibration automatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution
Conductivity Range 0.00 to 6.00 mS/cm
Conductivity Resolution 0.01 mS/cm
Conductivity Accuracy ±2% F.S.
TDS Range 0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF)
TDS Resolution 10 ppm (mg/L)
TDS Accuracy ±2% F.S.
Temperature Range 0.0 to 60.0°C / 32.0 to 140.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C /±1°F
Temperature Compensation pH: automatic; EC/TDS: automatic with β set at 1.9%/°C
EC/TDS Calibration automatic, one-point at 1.41 mS/cm or 5.00 mS/cm; one point calibration using quick calibration solution
TDS Conversion Factor 0.5 (500 ppm) or 0.7 (700 ppm)
Battery Type/Life 1.5V (4) / approx. 100 hours of continuous use, auto-off after 8 minutes of non-use
Auto-off after 8 minutes, 60 minutes, disabled
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 163 x 40 x 26 mm (6.4 x 1.6 x 1.0’’)
Weight 100 g (3.5 oz.)
Ordering Information HI98131 is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries (4), instructions and quality certificate.

Warranty Information: The fastest way to handle warranty issues is by contacting Hanna Instruments directly. If you prefer, you can always contact us directly and we will help facilitate the return. After purchasing your Hanna product, you may register for warranty on their website www.hannainst.com/hydroponics or retain your receipt as proof of purchase. Contact Hanna Tech Support with your valid proof of purchase at [email protected] or 800-426-6287 to be issued a Return Goods Authorization.

More Information
SKU 9448
Manufacturer's Suggested Retail Price $259.95
Dimensional/Billable Weight (lbs) 0.33
Actual Product Weight .33
Length (in.) 7
Width (in.) 2
Height (in.) 1
Model HI98131
Brand Hanna
Vendor Item # HI98131
UPC 80000981318
Manufacturer Warranty Yes
Write Your Own Review
You're reviewing:GroLine Combo Waterproof pH/EC/TDS/Temperature Tester
Your Rating