{"product_id":"hanna-hi98311-dist-r-5-ec-tds-temperature-tester","title":"Hanna HI98311 DiST® 5 EC\/TDS\/Temperature Tester","description":"\u003cp\u003e\u003cimg alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe HI98311 is an advanced, waterproof conductivity and TDS (ppm) tester for quick and easy measurements while on the go.\u003c\/p\u003e\n\u003cp\u003eThis lightweight, waterproof conductivity tester offers accurate conductivity (0 to 3999 µS\/cm), TDS (0 to 2000 ppm), and temperature measurements in a single, portable, pocket device. No more switching between meters for your routine measurements.\u003c\/p\u003e\n\u003cp\u003eCompact \u0026amp; waterproof design fits right in your pocket so you can take it anywhere. Replaceable graphite electrode extends the life of your tester for years. Great for hydroponics, aquariums, pools, \u0026amp; ponds.\u003c\/p\u003e\n\u003cp\u003eDetails\u003c\/p\u003e\n\u003cp\u003eWhen the original DiST® (Dissolved Solids Tester) was first introduced, conductivity and total dissolved solids measurements became easy and affordable. The DiST’s ease of use, in combination with its affordability, made it the standard in EC and TDS measurement. Hanna continues the standard in EC and TDS testing with the DiST®5.\u003c\/p\u003e\n\u003cp\u003eThis conductivity tester includes features such as a replaceable graphite electrode, adjustable TDS ratio, °C or °F measurement, Automatic Temperature Compensation (ATC) with adjustable β, battery level indicator, stability indicator, automatic shut-off and automatic calibration.\u003c\/p\u003e\n\u003cp\u003eThe graphite conductivity electrode offers greater accuracy by resisting contamination by salt deposits in the sample. All of these features are packed in a floating, waterproof casing. This 3-in-1 tester is unmatched in EC, TDS, and temperature measurements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConductivity Range\u003c\/th\u003e\n\u003cth\u003e0 to 3999 µS\/cm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Accuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 1413 µS\/cm, 1382 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic, with β adjustable from 0.0 to 2.4% \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 100 hours of continuous use, auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode\/Probe\u003c\/td\u003e\n\u003ctd\u003eHI73311 replaceable EC\/TDS graphite electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003eHI98311 (DiST®5) is supplied with HI73311 EC\/TDS probe, HI73128 probe removal tool, batteries and instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments, Inc.","offers":[{"title":"Default Title","offer_id":41930560536661,"sku":"11981","price":135.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0610\/3426\/6709\/files\/hanna-hi98311-dist-5-ectdstemperature-tester-11981-3786348.jpg?v=1767475207","url":"https:\/\/www.bghydro.com\/products\/hanna-hi98311-dist-r-5-ec-tds-temperature-tester","provider":"BetterGrow Hydro","version":"1.0","type":"link"}